Loading...

Vertical Retracting

Windows & Doors

For A Better View

  • Alternative to sliding, swinging or folding windows & doors,
  • More glass, less frame (up to 6m without vertical profiles),
  • No counterweights, easy retrofit option

4 VARIATIONS TO SUIT YOUR NEED

One Size Does Not Suit All

Ideal for mild climate installations where extreme thermal insulation is not a priority, and the cost is!

6 different Window, Door, and Countertop configurations, are available for 50%, 66% net opening.

Sizes ranging from 3.6m width to 3.6m in height,

New or retrofit installation with ease,

Non-thermally broken profile system,

Frames will accept Single or IG of up to 20mm

Ideal where design flexibility, excellent weather, and thermal performance are of importance,

8 different Window or Door configurations, available for 50%, 66% or 75% net opening,

Sizes ranging from 5.0m in width to 6.0m in height,

New or retrofit installation with ease,

Designed with a thermally broken structural system, motor box, and window,

Frames will accept IG of up to 32mm

Ideal for Curtain wall or Residential applications, excellent weather, and thermal performance,

2 different Window or Door configurations, available for 50% net opening,

Sizes ranging from 5.0m in width to 6.0m in height,

New or retrofit installation with ease,

Designed with a thermally broken structural system, motor box, and window frames,

Frames will accept IG of up to 38mm

Ideal for large spans of up to 6m, excellent thermal insulation. Industry leader screw drive, advanced PLC-based control system that sets industry standards in safe operation and controls flexibility.

4 different Window or Door configurations, available in 66% or 75% net opening

Sizes range from 6m in width to 5m in height and the total operable weight limit ok 900Kg.

New or retrofit installation with ease,

Designed with a thermally broken structural system, motor box, and window frame

PANORA (GU) SYSTEMS PRODUCTION PROGRAM & OPTIONS

MAX (GUL)MAXI (GUM GUM+)MAXI FAÇADE (GUF GUF+)MAXIMA (GUG+)
StandardStandard GUMOptional GUM+Standard GUFOptional GUF+Standard GUGOptional GUG+
Mechanical & Electrical
Motor Type & Input Voltage120 Nm / 12 RPM 220 VAC/50Hz120 Nm / 12 RPM 220 VAC/50Hz300 Nm / 12 RPM 220 VAC/50Hz120 Nm / 12 RPM 220 VAC/50Hz300 Nm / 12 RPM 220 VAC/50Hz0.37kW x 2, 3-Phase Motor. 220VAC/50Hz
Drive SystemTubular motor direct drive, 12.7mm chain drive system (1/2")Tubular motor direct drive, 12.7mm chain drive system (1/2")Tubular motor with proprietary gearbox. 12.7mm chain drive(1/2")Tubular motor with proprietary gearbox. 12.7mm chain drive(1/2")Vertical Screw Drive
Open & Close speed m/minTable DataTable DataTable DataTable DataTable DataTable DataTable Data
Control SystemTable DataTable DataTable DataTable DataTable DataTable DataTable Data
Closed Door LockTable DataTable DataTable DataTable DataTable DataTable DataTable Data
Safety SensorsTable DataTable DataTable DataTable DataTable DataTable DataTable Data
Motor Box & System WidthTable DataTable DataTable DataTable DataTable DataTable DataTable Data
Structural
Motor Type & Input Voltage120 Nm / 12 RPM 220 VAC/50Hz120 Nm / 12 RPM 220 VAC/50Hz300 Nm / 12 RPM 220 VAC/50Hz120 Nm / 12 RPM 220 VAC/50Hz300 Nm / 12 RPM 220 VAC/50Hz0.37kW x 2, 3-Phase Motor. 220VAC/50Hz
Drive SystemTubular motor direct drive, 12.7mm chain drive system (1/2")Tubular motor direct drive, 12.7mm chain drive system (1/2")Tubular motor with proprietary gearbox. 12.7mm chain drive(1/2")Tubular motor with proprietary gearbox. 12.7mm chain drive(1/2")Vertical Screw Drive
Open & Close speed m/minTable DataTable DataTable DataTable DataTable DataTable DataTable Data
Control SystemTable DataTable DataTable DataTable DataTable DataTable DataTable Data
Closed Door LockTable DataTable DataTable DataTable DataTable DataTable DataTable Data
Safety SensorsTable DataTable DataTable DataTable DataTable DataTable DataTable Data
Motor Box & System WidthTable DataTable DataTable DataTable DataTable DataTable DataTable Data
Standards
Watertightness EN 12208Class 5A (at 250 Pa)120 Nm / 12 RPM 220 VAC/50Hz300 Nm / 12 RPM 220 VAC/50Hz120 Nm / 12 RPM 220 VAC/50Hz300 Nm / 12 RPM 220 VAC/50Hz0.37kW x 2, 3-Phase Motor. 220VAC/50Hz
Resistance to Safety Load EN 12220Tubular motor direct drive, 12.7mm chain drive system (1/2")Tubular motor direct drive, 12.7mm chain drive system (1/2")Tubular motor with proprietary gearbox. 12.7mm chain drive(1/2")Tubular motor with proprietary gearbox. 12.7mm chain drive(1/2")Vertical Screw Drive
Air Permeability EN 12207Table DataTable DataTable DataTable DataTable DataTable DataTable Data
Resistance to Wind Load EN 12210Table DataTable DataTable DataTable DataTable DataTable DataTable Data
Maximum Thermal Insulation (Uw)Table DataTable DataTable DataTable DataTable DataTable DataTable Data

PANORA (GU) SYSTEMS PRODUCTION PROGRAM & OPTIONS